FRP029
ポスターセッション③ 8月8日 7-1F-B 10:00-12:00
高温超伝導空芯サイクロトロンの設計および実現性の研究
Design and feasibility study of an HTS air-core cyclotron
○荘 浚謙1, 松田 洋平1, 福田 光宏1, 依田 哲彦1, 神田 浩樹1, 趙 航1, Shali Ahsani Hafizhu1, 松井 昇大朗1, 板倉 菜美1, 石畑 翔1, 辻坂 匡1, 石山 敦士2, 野口 聡3, 植田 浩史4, 吉田 潤5(1大阪大学核物理研究センター, 2早稲田大学, 3北海道大学, 4岡山大学, 5住友重機械)
○Tsun Him Chong1, Yohei Matsuda1, Mitsuhiro Hukuda1, Tetsuhiko Yorita1, Hiroki Kanda1, Hang Zhao1, Shali Ahsani Hafizhu1, Shotaro Matsui1, Nami Itakura1, Sho Ishihata1, Tasuku Tsujisaka1, Atsushi Ishiyama2, So Noguchi3, Hiroshi Ueda4, Jun Yoshida5(1RCNP, Osaka U., 2Waseda U., 3Hokkaido U., 4Okayama U., 5Sumitomo Heavy Industries Ltd.)
An air-core cyclotron uses HTS coils as magnets. Previous studies have verified the feasibility of beam injection, acceleration, and extraction using this air-core cyclotron. However, some problems remain unsolved. Previous study investigated the beam properties of the cyclotron without considering the HTS coil properties. Also, the fabrication cost and cyclotron volume also need to be reduced for the cyclotron to be put into practical use. In this presentation, a modified air-core cyclotron model is presented, which is designed to satisfy the engineering requirement from HTS coils. The cyclotron volume, the magnetic field property, and its feasibility as a medical cyclotron are discussed.